體細胞核轉移(SCNT)/制備雜交瘤轉染系統-細胞分析儀器-儀器設備-生物在線
世聯博研(香港)科技有限公司
體細胞核轉移(SCNT)/制備雜交瘤轉染系統

體細胞核轉移(SCNT)/制備雜交瘤轉染系統

商家詢價

產品名稱: 體細胞核轉移(SCNT)/制備雜交瘤轉染系統

英文名稱: Somatic-Cell Nuclear Transfer (SCNT)/Hybridoma Production

產品編號: LF101

產品價格: 0

產品產地: 日本

品牌商標: nepagene

更新時間: null

使用范圍: null

世聯博研(香港)科技有限公司
  • 聯系人 :
  • 地址 : 北京市海淀區西三旗上奧世紀中心A座9層906
  • 郵編 :
  • 所在區域 : 北京
  • 電話 : 186****1725 點擊查看
  • 傳真 : 點擊查看
  • 郵箱 : 787852745@qq.com

LF101 Electro Cell Fusion Generator

Somatic-Cell Nuclear Transfer (SCNT)/Hybridoma Production

LF101 Electro Cell Fusion Generator

LF101 Applications

  • Somatic-Cell Nuclear Transfer (SCNT) for Bovine, Pigs, Mice, Rabbits, etc.
  • Hybridoma Production for Monoclonal Antibodies
  • Plant Protoplast Fusion
  • Egg Activation

LF101 Features

point Specialized setting for bovine, pig, mouse and rabbit cloning (somatic cell and embryo nuclear transplant) will result in extremely high fusion probability (for example: more than 90% for bovine cloning).
point Voltage setting with 1V resolution is possible in the specialized setting for mammalian cloning. It is suitable to output precisely the square pulse wave shape and pulse range as preset and accordingly brings about a higher rate of cell fusion probability.
point Post fusion function for damage recovery of the cell can be operated with On/Off switching.
point Specialized setting for plant protoplast and mammalian cell fusion can provide a desirable condition for the cell fusion, which is done with DC pulse (100V, max.) of the precisely controlled voltage and pulse range after producing the pearl chains with DC. It can elevate the rate of hybridoma production (cell fusion) probability.
point Operation of the device is very easy because both of automatic and manual (number of pulses: 1-99) transmitting of the pulse are possible. And the pulse interval can be selected to set between 0.1-9.9 seconds. The device can keep a constant operating condition anytime.
point NEPA GENE provides a variety of electrodes for combination use with the device, which is designed to match well with its various settings through our long accumulated experiences. Combination use of the electrodes with the device enables very easy and efficient gene transfection and cell fusion.

LF101 Specifications

point AC Pulse

Wave Shape Sine Wave
Voltage 0 - 50V (VP-P)
Frequency 0.1 - 3.9MHz Variable
Duration 0 - 99s
Post Fusion 0~9sec (On?Offスイッチ)
Shunt Resistor Greater than 50 ohm

point DC Pulse

Wave Shape Square
Voltage 0 - 999V
0 - 200V (1V resolution)
Pulse Length Range 5~99μs (1μs resolution)
Pulse interval 0.1~9.9s
Number of Pulses 0 - 99 Automatic or Manual
Power 100V (50/60Hz) 2A
Size / Weight 375W×430D×160H mm , 12.7kg