HISTRAP FF CRUDE-色譜柱 -耗材-生物在線
上?;巧锟萍加邢薰?>
        </div>

        <!-- shop-details-area -->
        <section class=
HISTRAP FF CRUDE

HISTRAP FF CRUDE

商家詢價

產品名稱: HISTRAP FF CRUDE

英文名稱: HISTRAP FF CRUDE

產品編號: 11-0004-58

產品價格: 0

產品產地: 美國

品牌商標: GE

更新時間: null

使用范圍: null

11-0003-29 HITRAP DESALTING 100 X 5 ML
11-0004-58 HISTRAP FF CRUDE 5X1 ML
11-0004-59 HISTRAP FF CRUDE 100X1 ML
11-0004-64 STOP PLUG FEMALE, 1/16''
11-0013-02 HITRAP CAPTO Q, 5X1ML
11-0013-03 HITRAP CAPTO Q, 5X5ML
11-0032-73 HITRAP CAPTO MMC, 5X1ML
11-0032-75 HITRAP CAPTO MMC, 5X5ML
11-0034-93 HITRAP MABSELECT SURE, 5X1ML
11-0034-94 HITRAP MABSELECT SURE, 1X5ML
11-0034-95 HITRAP MABSELECT SURE, 5X5ML
17-0402-01 HITRAP PROTEIN A HP, 5 X 1 ML
17-0402-03 HITRAP PROTEIN A HP,2 X 1 ML
17-0403-01 HITRAP PROTEIN A HP,1 X 5 ML
17-0403-03 HITRAP PROTEIN A HP, 5 X 5 ML
17-0404-01 HITRAP PROTEIN G HP, 5 X 1 ML
17-0404-03 HITRAP PROTEIN G HP, 2 X 1 ML
17-0405-01 HITRAP PROTEIN G HP,1 X 5 ML
17-0405-03 HITRAP PROTEIN G HP, 5 X 5 ML
17-0406-01 HITRAP HEPARIN HP, 5 X 1 ML
17-0407-01 HITRAP HEPARIN HP,1 X 5 ML
17-0407-03 HiTrap Heparin HP 5x5ml

HisTrap? FF crude Columns/HisTrap FF crude Kit - Convenient Purification from Unclarified Lysates

  • Optimized for purification of histidine-tagged* proteins directly from homogenized, unclarified cell lysates.
  • Simply homogenize and load your sample directly.
  • High binding capacity, approx. 40 mg/ml medium and negligible Ni2+ leakage.
  • Compatible with a wide range of reducing agents, detergents, denaturants and other additives.
  • Convenient kit provides columns and buffers for quick and easy purifications.
  • Simple operation with a syringe, pump, or chromatographic system such as ?KTAdesign.

HisTrap? FF crude Columns/HisTrap FF crude Kit - Convenient Purification from Unclarified Lysates

Technical Information


* For licensing information, see Legal Info.

?

Customer feedback on Ni Sepharose 6 Fast Flow.

?

TECHNICAL SPECIFICATIONS
Medium? Ni Sepharose 6 Fast Flow?
Column volume? 1 ml and 5 ml?
Column dimensions? 0.7 × 2.5 cm (1 ml)
1.6 × 2.5 cm (5 ml)?
Dynamic binding capacity*? Approx. 40-mg histidine-tagged protein/ml medium?
Recommended flow rate?? 1 ml/min (1 ml)
5 ml/min (5 ml)?
Max. pressure?? 3?bar (0.3 MPa, 42 psi)?
Compatibility ?during use? Stable in all commonly used buffers, reducing agents, denaturing agents and detergents, see Ni Sepharose? High Performance - High-performance Purification?
Chemical stability?? For one week at 40°C: 0.01 M HCl, 0.1 M NaOH
For 12 h: 1 M NaOH, 70% acetic acid
30 min tested: 30% 2-propanol
1 h tested: 2% SDS?
pH stability?? 2-14 (short term), 3-12 (long term)?
Storage? 20% ethanol?
Storage temperature? +4°C to 30°C?
*?Protein-dependent
??H2O at room temperature
??Ni2+-stripped medium

?

?

Click here to view this image in high resolution
HisTrap? FF crude columns allow simple, one-step purification of histidine-tagged proteins without sample pretreatment such as centrifugation and filtration.

?

HisTrap? FF crude 1-ml and 5-ml columns offer the convenience of simple, one-step purification of histidine-tagged proteins directly from homogenized, unclarified cell lysates. Direct loading of unclarified sample both saves time and prevents degradation of sensitive target protein.

?

HisTrap? FF crude columns are prepacked with Ni Sepharose? 6 Fast Flow. For more information see Ni Sepharose? 6 Fast Flow - Scale-up Purification. For column technical specifications, see HisTrap? FF Columns - Easy Scale-up Purification (HisTrap? FF Columns). For best results, we recommend first addition of lysozyme and DNase I followed by a mechanical lysis, e.g. by sonication. The homogenized sample can then be loaded directly on the column without a clarification step which may prevent degradation of the target protein and increase the activity.

?

HisTrap FF crude Kit provides convenient purification of histidine-tagged proteins. The kit contains three HisTrap FF crude 1-ml columns, phosphate buffer, pH 7.4 (2 × 50 ml [8× concentrate]), 2 M imidazole, pH 7.4, all necessary connectors, a syringe, and instructions.

?

Click here to view this image in high resolution
Four repeated purifications of MBP-(His)6 from E. coli extract on HisTrap FF crude 1?ml. The medium was subjected to Ni2+-ion stripping, cleaning-in-place, and recharging between runs.

?

Click here to view this image in high resolution
HisTrap FF crude columns save time in the purification of histidine-tagged proteins compared to conventional IMAC.